Telecommunications · radio
Towers, antennas and radio links for critical sites
We assess field packages for telecommunications infrastructure: survey, structural interfaces, antennas, feeders, fibre, power, grounding, alignment and testing. Qualified personnel, access equipment, procedures and deliverables are confirmed for each site.
Scope, resources, qualifications and schedule are confirmed following technical review of the project.
Scope and decisions
A link is not complete when the antenna is mounted; it is complete when the path is aligned, tested and documented.
Availability depends on structure, line of sight, polarisation, power, grounding, cabling, sealing, configuration and coordination between both ends. Every acceptance condition is tied to field evidence.
Tower and supports
Inspection, installation or adaptation of structures, mounts, vertical cabling and site organisation.
- Survey and access
- Mounts and cable routes
- Torque and labelling
Radio and antennas
Installation, orientation, polarisation, feeders, fibre, power and associated equipment.
- End-to-end alignment
- Sealing and protection
- Link testing
Maintenance
Preventive and corrective interventions on infrastructure, power, cabling and field components.
- Diagnostics
- Spares and contingency
- Close-out report
Method
Work sequence
Survey
We confirm location, access, height, structure, path, power, grounding and risks.
Field engineering
We validate mounts, routes, loads, orientation, cables, interfaces and sequence.
Preparation
We close permits, personnel, rescue, tools, instruments, spares and communications.
Installation
Installation of mounts, antennas, feeders, fibre, power, grounding, labels and protection according to the approved scope.
Alignment and testing
We coordinate both ends, adjust parameters and verify levels and stability.
Close-out
We hand over photographs, readings, inventory, redlines and maintenance observations.
Required inputs
Information required to quote without hidden assumptions
Correct inputs turn a general requirement into an executable, measurable and quotable scope.
- Coordinates and heights of both ends
- Path profile and line of sight
- Frequency, capacity and radio configuration
- Antenna model, weight and wind load
- Tower or support type and condition
- Feeder, fibre and power routes
- Power and backup availability
- Grounding and surge protection
- Access, work-at-height and rescue permits
- Test values and acceptance format
Commercial engineering
What drives price and schedule
Height and access
Tower type, climbing, weather, roads, lifting and dwell time define crew and safety.
Coordination between ends
Alignment requires simultaneous availability, communications and configuration control.
Power and grounding
Rectifiers, batteries, boards, protection and grounding may expand the field package.
Spares and SLA
On-call coverage, response time, stock, travel and criticality define maintenance cost.
Acceptance
Deliverables and close-out documentation
The package is complete when the technical result and the supporting records can be accepted.
- Site and structure checklist
- Installation and torque records
- Route, sealing and labelling photographs
- Alignment and link-level values
- Equipment and serial inventory
- Report, redlines and close-out dossier
Related services
Continue the technical journey.
Frequently asked questions
Questions that change scope, price or acceptance.
Can you provide field services only?
Yes. We can act as the field arm of an operator or integrator with engineering, configuration and responsibility boundaries defined.
Can alignment be included?
Yes, subject to equipment, access and availability at the remote end, including recorded signal levels.
Can you work at sites without stable power?
Yes, by combining radio scope with power, backup, batteries, solar, generator and monitoring solutions.
What is required to quote maintenance?
Site list, SLA, criticality, inventory, spares, access, permits and on-call requirements.
Next step
Send coordinates, heights and link equipment.
State structure, radios, antennas, power, access, date and test criteria. We return gaps and a site-by-site scope.